Units purchased online qualify for free shipping*.
See specific product to be purchased for shipping method to be used. Following purchase of unit to be shipped via LTL, contact Thermaco at 1-800-633-4204 to verify shipping details and schedule delivery.
*Online ordering and free shipping only available in contiguous or lower 48 states in US. All other locations should contact local representation or Thermaco for additional assistance in purchasing items.
Sometimes space restrictions require the installation of Big Dipper and Trapzilla units in basement locations where significant head pressure becomes a factor. The VFCA-100 Vented Flow Control module provides an option for use with installations where significant head pressure is present (greater than 6′ [1.95 m]) or where applicable regulations require vented flow controls. The Vented Flow Control helps reduce problems associated with high head pressure and helps slow the drainwater flow down the pipe, preventing it from exceeding 100 gallons per minute (6.31 l/s). Includes appropriate PVC fitting and flow stainless steel flow control orifice.
Sometimes space restrictions require the installation of Big Dipper and Trapzilla units in basement locations where significant head pressure becomes a factor. The VFCA-125 Vented Flow Control module provides an option for use with installations where significant head pressure is present (greater than 6′ [1.95 m]) or where applicable regulations require vented flow controls. The Vented Flow Control helps reduce problems associated with high head pressure and helps slow the drainwater flow down the pipe, preventing it from exceeding 125 gallons per minute (7.89 l/s). Includes appropriate PVC fitting and flow stainless steel flow control orifice.
Sometimes space restrictions require the installation of Big Dipper and Trapzilla units in basement locations where significant head pressure becomes a factor. The VFCA-35 Vented Flow Control module provides an option for use with installations where significant head pressure is present (greater than 6′ [1.95 m]) or where applicable regulations require vented flow controls. The Vented Flow Control helps reduce problems associated with high head pressure and helps slow the drainwater flow down the pipe, preventing it from exceeding 35 gallons per minute (2.21 l/s). Includes appropriate PVC fitting and flow stainless steel flow control orifice.
Sometimes space restrictions require the installation of Big Dipper and Trapzilla units in basement locations where significant head pressure becomes a factor. The VFCA-50 Vented Flow Control module provides an option for use with installations where significant head pressure is present (greater than 6′ [1.95 m]) or where applicable regulations require vented flow controls. The Vented Flow Control helps reduce problems associated with high head pressure and helps slow the drainwater flow down the pipe, preventing it from exceeding 50 gallons per minute (3.15 l/s). Includes appropriate PVC fitting and flow stainless steel flow control orifice.
Sometimes space restrictions require the installation of Big Dipper and Trapzilla units in basement locations where significant head pressure becomes a factor. The VFCA-75 Vented Flow Control module provides an option for use with installations where significant head pressure is present (greater than 6′ [1.95 m]) or where applicable regulations require vented flow controls. The Vented Flow Control helps reduce problems associated with high head pressure and helps slow the drainwater flow down the pipe, preventing it from exceeding 75 gallons per minute (4.73 l/s). Includes appropriate PVC fitting and flow stainless steel flow control orifice.
Convenient Replacement Packets of Active Carbon Pellets for the Big Dipper Carbon Filter. Each packet contains 9 oz. of activated carbon pellets. Simply empty the entire 9-oz. packet into the Carbon Vent Filter container and replace lid. Replace Active Carbon Pellets every 3 months for best results.
Convenient Replacement Packets of Active Carbon Pellets for the Big Dipper Carbon Vent Filter. Each packet contains 9 oz. of activated carbon pellets. Simply empty one entire 9-oz. packet into the Carbon Vent Filter container and snap on the lid. Replace Active Carbon Pellets every 3 months for best results.
Installation Instructions: Simply fit the narrow end of the Carbon Vent Filter into any 2-in. no-hub coupling or venting pipe opening where odor is a concern. Coupling sizes needed:
1”-2” for 1” vent
2”-2” for 2” vent
3”-2” for 3” vent
4”-2” for 4” vent
Replace with new Carbon Vent Pellets every 3 months for best results.
Thermaco Trapzilla ECA-TSS-29 Two-Piece Extension Collar with telescoping design and ladder grooves, allowing for precise sizing in the field, offering an additional 29″ (73.7 cm) of extension for Trapzilla Solids Separator Units installed in-ground. ECA-TSS-29 is compatible with 18″ (45.72 cm) Single-Piece Extension Collar found on In-Ground (-ECA) Models and Standard Adapter Ring found on Basic Models. Installed with In-Ground (-ECA) Models, Trapzilla Solids Separator Unit has 47″ (119.4 cm) of extension to bring lid to ground level.
The Trapzilla ECA-TZ-29 Two-Piece Extension Collar with telescoping design and ladder grooves, allows for precise sizing in the field, offering an additional 29″ (73.7 cm) of extension for Trapzilla Units installed in-ground. ECA-TZ-29 is compatible with 18″ Single-Piece Extension Collar found on In-Ground (-ECA) Models and Standard Adapter Ring found on Basic Models. Installed with In-Ground (-ECA) Models, Trapzilla Unit has up to 47″ of extension to bring lid to ground level.
The FTCA-22 Top Cover takes the place of the 22″ Diameter Solid Top Cover and is compatible with the TZ-160, Standard Adapter Top Cover, all Trapzilla-ECA models with ECA-18, and ECA-TZ-29. It provides a durable, non-slip, diamond plate surface for installation in high foot-traffic areas such as a kitchen floor.
For a H20 traffic-rated solution, refer to our traffic rated drawings here.
GrabSampler may be used in conjunction with any sampling port. Simply place a 1 Liter Jar into the carrier which snugly holds the jar, set the carrier to the correct angle and tighten using a nut driver and the wing screw and lower into the sampling port using a paint stick (purchased separately at home improvement stores).
Thermaco, Inc. supplies the frame, support base, and one SSA-160 with the HA-160. This includes four (4) 36” threaded rods and the nuts to connect to a contractor-installed, in-floor suspension mount. This kit needs to be installed by a licensed contractor. The contractor is responsible for determining weight loads, preparation of the floor for installation and any construction necessary for installation of the suspension kit.
*Trapzilla Unit must be purchased separately
**HA-400/600 Pictured Left. See HA-160 specs for correct dimensions.
Thermaco, Inc. supplies the frame, support base, and one SSOP-400/600 with the HA-400/600. This includes four (4) 36” threaded rods and the nuts to connect to a contractor-installed, in-floor suspension mount. This kit needs to be installed by a licensed contractor. The contractor is responsible for determining weight loads, preparation of the floor for installation and any construction necessary for installation of the suspension kit.
Thermaco, Inc. supplies the frame, support base, and one SSOP-70/95 with the HA-70/95. This includes four (4) 36” threaded rods and the nuts to connect to a contractor-installed, in-floor suspension mount. This kit needs to be installed by a licensed contractor. The contractor is responsible for determining weight loads, preparation of the floor for installation and any construction necessary for installation of the suspension kit.
*Trapzilla Solids Separator Unit must be purchased separately